by University of California, Irvine

Revolutionary new approach for 3D CT imaging from a single X-ray projection

Traditional CT (left) vs. XACT (right): XACT eliminates the need for gantry rotation to reconstruct a 3D image, offering a more portable and faster imaging solution. Credit: Science Advances (2024). DOI: 10.1126/sciadv.ads1584

Computed tomography (CT) has long been a cornerstone of modern imaging, providing detailed 3D insights into the human body and other materials. However, conventional CT requires hundreds of X-ray projections from multiple angles, exposing patients to significant radiation doses and relying on large, immobile systems.

To address this issue, researchers from UC Irvine's Departments of Radiological Sciences and Biomedical Engineering recently published a study in the journal Science Advances in which they introduce a technology that achieves 3D imaging with a single X-ray projection called X-ray–Induced Acoustic Computed Tomography (XACT).

A new paradigm in imaging

"In XACT, the generated sound waves by X-rays change the way X-ray imaging works, converting X-rays to ultrasound. X-rays typically travel in straight lines, so one projection only provides 2D information. However, X-ray-induced acoustic signals propagate in three dimensions, allowing for 3D imaging with a single projection," said Shawn Xiang, Ph.D., the study's corresponding author and an associate professor at UCI's Departments of Radiological Sciences and Biomedical Engineering.

XACT leverages the interaction between X-rays and tissue to produce acoustic waves, which travel at a speed of 1,500 meters per second. These waves are captured by ultrasound detectors, enabling real-time, three-dimensional imaging without the need for mechanical scanning or complex gantry systems.

"For the first time, we have proved that 3D imaging can be obtained with a single X-ray projection based on X-ray-induced acoustic detection in both phantoms and biological tissue," said Siqi Wang, Ph.D., the study's first author. Wang completed his Ph.D. at UCI in Xiang's lab and is now a postdoctoral research scholar at Stanford University.

"The groundbreaking finding here is that you can make 3D X-ray imaging with just a single projection, which typically needs 600 projections or more," says Vahid Yaghmai, MD, MS, FSAR, a radiologist at UC Irvine and chair of the UC Irvine Department of Radiological Sciences, who was not directly involved in the study.

Revolutionary new approach for 3D CT imaging from a single X-ray projection

The above graphics illustrate what 3D imaging with XACT looks like with examples of the UC logo on the left and a bone sample on the right. Credit: Adapted from Science Advances (2024). DOI: 10.1126/sciadv.ads1584

Benefits beyond traditional CT

One of XACT's most significant advantages is its efficiency and reduced radiation exposure. This makes XACT a safer and more accessible alternative, particularly for applications like routine diagnostics and breast cancer screening. Furthermore, with portable X-ray sources and ultrasound detectors, XACT systems promise compact, gantry-free designs, enabling imaging in settings previously inaccessible to traditional CT systems.

While the potential of XACT is immense, current limitations include resolution constraints tied to the frequency and size of the ultrasound detectors. Future improvements, such as higher-frequency transducers and advanced reconstruction algorithms powered by deep learning, could further enhance its performance.

Redefining imaging across fields

The ability to achieve 3D imaging from a single X-ray projection positions XACT as a transformative tool not only for medical diagnostics but also for nondestructive testing in engineering and material science. Its innovative approach eliminates the need for rotational access, opening new possibilities for imaging in constrained environments.

XACT also represents a leap forward in imaging technology, combining reduced radiation exposure, compact system design and unprecedented efficiency. As this technology continues to evolve, it has the potential to redefine medical and industrial imaging, bringing us closer to a future where high-resolution, low-dose 3D imaging is the norm in health care and beyond.

More information: Siqi Wang et al, X-ray–induced acoustic computed tomography: 3D X-ray absorption imaging from a single view, Science Advances (2024). DOI: 10.1126/sciadv.ads1584

Journal information: Science Advances 

Provided by University of California, Irvine