by Daegan Miller, University of Massachusetts Amherst
Device concept and fabrication. a Schematic of the mesh-innervated CMT. b Schematic of the (i) cell-device interface, with the graphene device detecting (ii) the action potential by the field effect and (iii) mechanical strain by the piezoresistive effect. The schematic Ids illustrates expected current change in each stage. c Schematic of the layered structure in the mesh. d Optical image of a fabricated mesh before the release from substrate. Scale bar, 400 µm. e Optical image of the ribbon feature, Scale bar, 200 µm. f Optical image of the graphene transistor in the dashed box in (e). Scale bar, 20 µm. g Raman spectra of the graphene (blue) and SU-8 substrate (gray) at the locations indicated in (f). h Conductance (G)-water gate (Vg) relationship from 14 mesh-integrated graphene transistors mesh in Dulbecco’s phosphate-buffered saline (DPBS) solution. The line and shadow represent the mean value and standard deviation, respectively. The inset shows the test setup schematic, in which a gold wire immersed in DPBS solution is used as the water gate. i Average relative conductance change (∆G/G) in graphene transistors (n = 5 independent transistors) with respect to net strain. Data in (i) are presented as mean values ± SD. Credit: Nature Communications (2024). DOI: 10.1038/s41467-024-46636-7
A team of engineers led by the University of Massachusetts Amherst and including colleagues from the Massachusetts Institute of Technology (MIT) recently announced in Nature Communications that they had successfully built a tissue-like bioelectronic mesh system integrated with an array of atom-thin graphene sensors that can simultaneously measure both the electrical signal and the physical movement of cells in lab-grown human cardiac tissue.
In a research first, this tissue-like mesh can grow along with the cardiac cells, allowing researchers to observe how the heart's mechanical and electrical functions change during the developmental process. The new device is a boon for those studying cardiac disease as well as those studying the potentially toxic side effects of many common drug therapies.
Cardiac disease is the leading cause of human morbidity and mortality across the world. The heart is also very sensitive to therapeutic drugs, and the pharmaceutical industry spends millions of dollars in testing to make sure that its products are safe. However, ways to effectively monitor living cardiac tissue are extremely limited.
In part, this is because it is very risky to implant sensors in a living heart, but also because the heart is a complex kind of muscle with more than one thing that needs monitoring.
"Cardiac tissue is very special," says Jun Yao, associate professor of electrical and computer engineering at UMass Amherst's College of Engineering and the paper's senior author. "It has a mechanical activity—the contractions and relaxations that pump blood through our body—coupled to an electrical signal that controls that activity."
But today's sensors can typically only measure one characteristic at a time, and a two-sensor device that could measure both charge and movement would be so bulky as to impede the cardiac tissue's function. Until now, there was no single sensor capable of measuring the heart's dual properties without interfering with its functioning.
The new device is built of two critical components, explains lead author Hongyan Gao, who is pursuing his Ph.D. in electrical engineering at UMass Amherst. The first is a three-dimensional cardiac microtissue (CMT) grown in a lab from human stem cells under the guidance of co-author Yubing Sun, associate professor of mechanical and industrial engineering at UMass Amherst.
CMT has become the preferred model for in vitro testing because it is the closest analog yet to a full-size, living human heart. However, because CMT is grown in a test tube, it has to mature, a process that takes time and can be easily disrupted by a clumsy sensor.
The second critical component involves graphene—a pure-carbon substance only one atom thick. Graphene has a few surprising quirks to its nature that make it perfect for a cardiac sensor. Graphene is electrically conductive, and so it can sense the electrical charges shooting through cardiac tissue. It is also piezoresistive, which means that as it is stretched—say, by the beating of a heart—its electrical resistance increases.
And because graphene is impossibly thin, it can register even the tiniest flutter of muscle contraction or relaxation and can do so without impeding the heart's function, all through the maturation process. Co-author Jing Kong, professor of electrical engineering at MIT, and her group supplied this critical graphene material.
Gao, Yao, and their colleagues then embedded a series of graphene sensors in a soft, stretchable porous mesh scaffold they developed that has close structural and mechanical properties to human tissue and which can be applied non-invasively to cardiac tissue.
"No one has ever done this before," says Gao. "Graphene can survive in a biological environment without degrading for a very long time and not lose its conductivity, so we can monitor the CMT across its entire maturation process."
"This is crucial for a number of reasons," adds Yao. "Our sensor can give real-time feedback to scientists and drug researchers, and it can do so in a cost-effective way. We take pride in using the insights of electrical engineering to help build tools that can be useful to a wide range of researchers."
In the future, Gao says, he hopes to be able to adapt his sensor to grander scales, even to in vivo monitoring, which would provide the best possible data to help solve cardiac disease.
More information: Hongyan Gao et al, Graphene-integrated mesh electronics with converged multifunctionality for tracking multimodal excitation-contraction dynamics in cardiac microtissues, Nature Communications (2024). DOI: 10.1038/s41467-024-46636-7
Provided by University of Massachusetts Amherst
Post comments